Reasons for High Power Consumption of Vertical Glass Display Coolers

Source: Time:2016-06-28 11:11:01 views:

Today's society, large and small food stores almost all equipped with a drinks cabinet, even the grocery store is visible a drinks cabinet, then today would result in an increase to explain the reasons for power drinks cabinet
Today's society, almost all the supermarkets and convenience stores are equipped with one or more vertical glass display coolers for drinks bottle drinks beers ,dairy and other items.then today to explain the cause of increased power consumption reasons drinks cabinet, convenience store drinks cabinet power the reason is reflected in the following points. It can be manipulated to reduce the power consumption of convenience store drinks cabinet in accordance with the text of the guide.

Causes increase in power consumption is very large drinks cabinet, drinks cabinet convenience stores generally exclude convenience store freezer reasons other than their own consumption, power consumption is very much reflected in the general reason for usage and maintenance extent, the increase in convenience store drinks cabinet power of reason is reflected in the following points.

三门饮料冷藏展示柜

Three-section Vertical Glass Display Coolers


First, the room temperature should not exceed the standard

  Indoor temperature back to a certain extent affect the convenience store drinks cabinet cooling effect, where large temperature changes will increase the failure rate accessories, glass door display cabinet frame prone to fog, affect the cooling effect. We should try to maintain a stable store environment temperature, reduce the workload of the compressor. Ambient temperature has a direct impact on the freezer power. Ambient temperature

Increased heat will make the refrigerator slows down, the inside temperature drops slowly will lead to longer boot time, power consumption is increased. Take an ordinary refrigerator experimental data analysis, when the ambient temperature reaches 32 ℃, power consumption is about twice at 25 ℃, 30 ℃ power consumption is 1.6 to 1.8 times that of 25 ℃. Therefore, the freezer should be placed as far as possible away from heat, ventilation and shade in place as well. because

This should make the drinks cabinet placed on the backlight side, increased shading devices without affecting the convenience store business premise.

四门饮料冷藏展示柜

Four drinks refrigerated display cabinets


Second, set a reasonable temperature

  Each freezer has a temperature control by adjusting gear to adjust the refrigerator temperature, the higher the thermostat stalls, the lower the temperature inside the freezer. After the freezer reaches -18 ℃, 1 ℃ each drop is difficult, the more difficult it cool down, but less continuous operation minimum temperature can reach -24 ℃, but this time will be the same because of the temperature difference between inside and outside, cooling capacity lost more the emergence of a very long boot time
Even non-stop. This thermostat only for domestic refrigerators, but as a commercial freezer manufacturers, the convenience store freezer first brand to use Andre freezer thermostat, are precise microcomputer control cabinet display cabinet moderate temperature, the error is smaller, cabinet temperature at a glance; convenience store freezer series is set at the factory to shut down 3 degrees, 8 degrees boot, but it is certainly in the middle of the temperature difference

, Hot weather, when temperatures sometimes rise to 11-12 degrees, this phenomenon is the case of normal.

五门饮料冷藏展示柜

Five drinks refrigerated display cabinets


Third, avoid repeated opening stop drinks cabinet
 
     Repeatedly stop constantly open drinks cabinet will affect the life of repeatedly starting or stopping the process will increase the workload of the compressor, greatly increases the power consumption. In use in the drinks cabinet drinks cabinet not exactly need to be closed, try not to close the convenience store drinks cabinet, in order to ensure energy saving temperature can also follow the manufacturer's instructions.

     Fourth, to minimize the number of door.

 Open drinks cabinet door can feel the cold air ran out, and the air conditioning to run away would inevitably result in a temperature rise in the freezer, it will cause a delay in the thermostat temperatures reach down and cause the compressor to work long hours, power consumption increases Big.